Oakhill Passivhaus

download as PDF
Download
as PDF
New build house to passivhaus classic standard
Images Graphs Figures Description Strategies Building

Oakhill Passivhaus : Project images

Click on image to preview full size

South_Elevation_Shutters_Open.jpg
CO2 emissionsPrimary energy requirement
Energy target
PassivHaus

Energy and fuel use

Fuel use by type
Primary energy requirement
CO2 emissions
Renewables

Measured data from renewable generation is not yet available.

Fuel use

 Pre-developmentForecastMeasured
Electricity use - - -
Natural gas use- - -
Oil use- - -
LPG use- - -
Wood use- - -
Other Fuel - - -
 Pre-developmentForecastMeasured
Primary energy requirement - - -
Annual CO₂ emissions - - -
Annual space heat demand - 14.6 kWh/m².yr -

Renewable energy

Electricity generationForecastMeasured
Renewables Technology--
Other Renewables Tech--
Electricity consumed by generation --
Primary energy requirement
offset by renewable generation
--
Annual CO₂ emissions
offset by renewable generation
--

Calculation and targets

Whole house energy calculation method PHPP
Other whole house calculation method-
Energy target PassivHaus
Other energy targets-
Forecast heating load 11 W/m² demand

Airtightness

 DateResult
Pre-development air permeability test--
Final air permeability test27 May 20210.22m³/m².hr @ 50 Pascals

Project description

StageOccupied
Start date01 August 2020
Occupation date01 August 2021
Location Oakhill, Mayfield East Sussex  England
Build typeNew build
Building sectorPrivate Residential
Property typeDetached
Construction typeSoftwood frame
Other construction type
Party wall construction
Floor area 207
Floor area calculation method Treated Floor Area (PHPP)
Building certification  Passivhaus certified building Passivhaus certified building

Project Team

OrganisationMBC timber frame
Project lead person
Landlord or Client
ArchitectKoru Architects
Mechanical & electrical consultant Enhabit
Energy consultantJim Miller Design Ltd
Structural engineer
Quantity surveyor
ConsultantEtude
ContractorObject Assemble

Design strategies

Planned occupancy2
Space heating strategyASHP with under floor heating and towel rails
Water heating strategyASHP provides DHW
Fuel strategyMains electricity
Renewable energy strategy33No BiPVCo Flextron 2609mm x 358mm panels bonded to the zinc roof
Passive Solar strategy
Space cooling strategyExternal louvres for secure night time ventilation
Daylighting strategy
Ventilation strategyMVHR
Airtightness strategy Taped specialist airtight board
Strategy for minimising thermal bridges Majority of TBs modelled in Therm
Modelling strategyPHPP
Insulation strategy
Other relevant retrofit strategies
Contextual information

Building services

Occupancy2
Space heatingASHP
Hot waterASHP
VentilationMVHR
Controls
Cooking
Lighting
Appliances
Renewable energy generation systemPV
Strategy for minimising thermal bridges

Building construction

Storeys 2
Volume -
Thermal fabric area -
Roof description
Roof U-value -
Walls description
Walls U-value -
Party walls description
Party walls U-value -
Floor description
Floor U-value -
Glazed doors description
Glazed doors U-value - -
Opaque doors description
Opaque doors U-value - -
Windows description
Windows U-value - -
Windows energy transmittance (G-value) -
Windows light transmittance -
Rooflights description
Rooflights light transmittance -
Rooflights U-value -