CO2 emissionsPrimary energy requirement
Energy target
EnerPHit

Energy and fuel use

Fuel use by type
Primary energy requirement
CO2 emissions
Renewables

Measured data from renewable generation is not yet available.

Fuel use

 Pre-developmentForecastMeasured
Electricity use - - -
Natural gas use- - -
Oil use- - -
LPG use- - -
Wood use- - -
Other Fuel - - -
 Pre-developmentForecastMeasured
Primary energy requirement - - -
Annual CO₂ emissions - - -
Annual space heat demand - 20 kWh/m².yr 20 kWh/m².yr

Renewable energy

Electricity generationForecastMeasured
Renewables Technology--
Other Renewables Tech--
Electricity consumed by generation --
Primary energy requirement
offset by renewable generation
--
Annual CO₂ emissions
offset by renewable generation
--

Calculation and targets

Whole house energy calculation method PHPP
Other whole house calculation method-
Energy target EnerPHit
Other energy targets-
Forecast heating load 12 W/m² demand

Airtightness

 DateResult
Pre-development air permeability test--
Final air permeability test--

Project description

StageOccupied
Start date01 October 2017
Occupation date01 December 2017
Location London London  England
Build typeRefurbishment
Building sectorPrivate Residential
Property typeSemi-Detached
Construction typeSolid Brick
Other construction type
Party wall construction
Floor area 246
Floor area calculation method Treated Floor Area (PHPP)
Building certification  Passivhaus certified building Passivhaus certified building

Project Team

Organisation
Project lead personDominic ORiordan
Landlord or ClientPrivate
ArchitectDominic ORiordan
Mechanical & electrical consultant Hagop Heath-Matossian
Energy consultant
Structural engineerForm London
Quantity surveyor
Consultant
ContractorBow Tie Construction

Design strategies

Planned occupancy
Space heating strategy
Water heating strategy
Fuel strategy
Renewable energy strategy
Passive Solar strategy
Space cooling strategy
Daylighting strategy
Ventilation strategy
Airtightness strategy
Strategy for minimising thermal bridges
Modelling strategy
Insulation strategy
Other relevant retrofit strategies
Contextual information

Building services

Occupancy
Space heating
Hot waterNew System boiler 27kW
VentilationPaul, Novus 450Ventilation system with heat recovery system with an efficiency of 90%. The air handler is located on the ground floor near the entrance door within the building envelope.
Controls
Cooking
Lighting
Appliances
Renewable energy generation system
Strategy for minimising thermal bridges

Building construction

Storeys 4
Volume -
Thermal fabric area -
Roof description Pitched roof - 200mm Xtratherm EPS, flat roof 200mm Kingspan TR7
Roof U-value 0.11 W/m² K
Walls description 200mm Jablite EPS, 150mm XPS below ground, Icynene sprayfoam used in some key areas of basement to overlap external wall insulatin and slab insulation
Walls U-value 0.16 W/m² K
Party walls description
Party walls U-value -
Floor description 180mm Kingspan TF70
Floor U-value 0.11 W/m² K
Glazed doors description
Glazed doors U-value - -
Opaque doors description
Opaque doors U-value 0.59 W/m² K uninstalled
Windows description RATIONEL AURAPLUS TRIPLE GLAZED WINDOW4-20-4-18-6,8 Energy Std TghU g-value = 0.53 W/(m2K)g -value = 52 %Rationel, AURAPLUSExt: RAL9010 - Pure white / Int: RAL9010 - Pure WhiteGroove for window boardU w-value = 1.24 W/(m2K)
Windows U-value 0.52 W/m² K -
Windows energy transmittance (G-value) -
Windows light transmittance -
Rooflights description
Rooflights light transmittance -
Rooflights U-value -