Ringmer Passivhaus

download as PDF
Download
as PDF
New build 3 bedroom certified Passivhaus as a replacement of existing equestrian barn.
Images Graphs Figures Description Strategies Building

Ringmer Passivhaus : Project images

Click on image to preview full size

Ringmer_Passivhaus_Dec_2018_11.jpg
Ringmer_Passivhaus_Dec_2018_17.jpg
Ringmer_Passivhaus_Dec_2018_25.jpg
Ringmer_Passivhaus_Dec_2018_37.jpg
Ringmer_Passivhaus_Dec_2018_41.jpg
Ringmer_Passivhaus_Dec_2018_5.jpg
Ringmer_Passivhaus_Dec_2018_azleMcCormackYoung_LLP_43.jpg
CO2 emissionsPrimary energy requirement
Energy target
PassivHaus

Energy and fuel use

Fuel use by type
Primary energy requirement
CO2 emissions
Renewables

Measured data from renewable generation is not yet available.

Fuel use

 Pre-developmentForecastMeasured
Electricity use - - -
Natural gas use- - -
Oil use- - -
LPG use- - -
Wood use- - -
Other Fuel - - -
 Pre-developmentForecastMeasured
Primary energy requirement - - -
Annual CO₂ emissions - - -
Annual space heat demand - 14 kWh/m².yr -

Renewable energy

Electricity generationForecastMeasured
Renewables Technology--
Other Renewables Tech--
Electricity consumed by generation --
Primary energy requirement
offset by renewable generation
--
Annual CO₂ emissions
offset by renewable generation
--

Calculation and targets

Whole house energy calculation method PHPP
Other whole house calculation method-
Energy target PassivHaus
Other energy targets-
Forecast heating load 10 W/m² demand

Airtightness

 DateResult
Pre-development air permeability test--
Final air permeability test--

Project description

StageOccupied
Start date15 February 2018
Occupation date15 November 2018
Location Norlington, Ringmer East Sussex  England
Build type
Building sectorPrivate Residential
Property typeDetached
Construction type
Other construction typeSIPS
Party wall construction
Floor area 153
Floor area calculation method Treated Floor Area (PHPP)
Building certification  Passivhaus certified building Passivhaus certified building

Project Team

Organisation
Project lead personJames Galpin, Architect
Landlord or ClientPrivate Client
ArchitectJames Galpin, Hazle McCormack Young LLP
Mechanical & electrical consultant
Energy consultantEnhabit
Structural engineerAdrian Boult - Abstruct Ltd
Quantity surveyor
Consultant
ContractorRextone Ltd

Design strategies

Planned occupancy
Space heating strategy
Water heating strategy
Fuel strategy
Renewable energy strategy
Passive Solar strategy
Space cooling strategy
Daylighting strategy
Ventilation strategy
Airtightness strategy
Strategy for minimising thermal bridges
Modelling strategy
Insulation strategy
Other relevant retrofit strategies
Contextual information

Building services

Occupancy
Space heating
Hot water
Ventilation
Controls
Cooking
Lighting
Appliances
Renewable energy generation system
Strategy for minimising thermal bridges

Building construction

Storeys
Volume -
Thermal fabric area -
Roof description
Roof U-value -
Walls description
Walls U-value -
Party walls description
Party walls U-value -
Floor description
Floor U-value -
Glazed doors description
Glazed doors U-value - -
Opaque doors description
Opaque doors U-value - -
Windows description
Windows U-value - -
Windows energy transmittance (G-value) -
Windows light transmittance -
Rooflights description
Rooflights light transmittance -
Rooflights U-value -