River Studio

download as PDF
Download
as PDF
River Studio was an asbestos clad shed which has been transformed into a new Passivhaus Enerphit studio space for Sjolander da Cruz Architects.The building re-uses slab and structure to balance architecture and physics, providing a comfortable environment, maximising daylight and views and embracing the surrounding Warwickshire countryside.
Images Graphs Figures Description Strategies Building

River Studio : Project images

Click on image to preview full size

riverstudio_Sjlander_da_Cruz_Architects_1.jpg
CO2 emissionsPrimary energy requirement
Energy target
EnerPHit

Energy and fuel use

Fuel use by type
Primary energy requirement
CO2 emissions
Renewables

Measured data from renewable generation is not yet available.

Fuel use

 Pre-developmentForecastMeasured
Electricity use - - -
Natural gas use- - -
Oil use- - -
LPG use- - -
Wood use- - -
Other Fuel - - -
 Pre-developmentForecastMeasured
Primary energy requirement - - -
Annual CO₂ emissions - - -
Annual space heat demand - - -

Renewable energy

Electricity generationForecastMeasured
Renewables Technology--
Other Renewables Tech--
Electricity consumed by generation --
Primary energy requirement
offset by renewable generation
--
Annual CO₂ emissions
offset by renewable generation
--

Calculation and targets

Whole house energy calculation method
Other whole house calculation method-
Energy target EnerPHit
Other energy targets-
Forecast heating load -

Airtightness

 DateResult
Pre-development air permeability test--
Final air permeability test--

Project description

StageOccupied
Start date13 May 2013
Occupation date23 December 2013
Location Leamington Spa Warwickshire  England
Build typeRefurbishment
Building sectorCommercial
Property typeDetached
Construction typeOther
Other construction typeSIP panels, cedar cladding
Party wall construction
Floor area 172.8
Floor area calculation method Treated Floor Area (PHPP)
Building certification  Passivhaus certified building Passivhaus certified building

Project Team

OrganisationSjlander da Cruz Architects
Project lead personSjlander da Cruz Architects
Landlord or ClientSjlander da Cruz Architects
ArchitectSjlander da Cruz Architects
Mechanical & electrical consultant Alan Clarke
Energy consultantNick Grant (Elemental Solutions)
Structural engineerBob Johnson (Consulting Structural Engineers)
Quantity surveyor
ConsultantCertifier - WARM: Low Energy Building Practice
ContractorArden Construction Limited

Design strategies

Planned occupancy
Space heating strategy
Water heating strategy
Fuel strategy
Renewable energy strategy
Passive Solar strategy
Space cooling strategy
Daylighting strategy
Ventilation strategy
Airtightness strategy
Strategy for minimising thermal bridges
Modelling strategy
Insulation strategy
Other relevant retrofit strategies
Contextual information

Building services

Occupancy
Space heating
Hot water
Ventilation
Controls
Cooking
Lighting
Appliances
Renewable energy generation system
Strategy for minimising thermal bridges

Building construction

Storeys
Volume -
Thermal fabric area -
Roof description
Roof U-value -
Walls description
Walls U-value -
Party walls description
Party walls U-value -
Floor description
Floor U-value -
Glazed doors description
Glazed doors U-value - -
Opaque doors description
Opaque doors U-value - -
Windows description
Windows U-value - -
Windows energy transmittance (G-value) -
Windows light transmittance -
Rooflights description
Rooflights light transmittance -
Rooflights U-value -