Nash Terrace

download as PDF
Download
as PDF
5 homes built to PassivHaus standard in Highbury conservation area, North London. The development was granted planning at appeal. The short terrace replaced an undistinguished commercial building adjacent to a listed Georgian terrace. The building was manufactured from Brettstapel solid timber structural panels, insulated with recycled newsprint insulation and incorporates both rainwater harvesting and ground source heat pump technologies.
Images Graphs Figures Description Strategies Building

Nash Terrace : Project images

Click on image to preview full size

Nash_Terrace.jpg
CO2 emissionsPrimary energy requirement
Energy target
PassivHaus

Energy and fuel use

Fuel use by type
Primary energy requirement
CO2 emissions
Renewables

Measured data from renewable generation is not yet available.

Fuel use

 Pre-developmentForecastMeasured
Electricity use - - -
Natural gas use- - -
Oil use- - -
LPG use- - -
Wood use- - -
Other Fuel - - -
 Pre-developmentForecastMeasured
Primary energy requirement - - -
Annual CO₂ emissions - - -
Annual space heat demand - - -

Renewable energy

Electricity generationForecastMeasured
Renewables Technology--
Other Renewables Tech--
Electricity consumed by generation --
Primary energy requirement
offset by renewable generation
--
Annual CO₂ emissions
offset by renewable generation
--

Calculation and targets

Whole house energy calculation method
Other whole house calculation method-
Energy target PassivHaus
Other energy targets-
Forecast heating load -

Airtightness

 DateResult
Pre-development air permeability test--
Final air permeability test--

Project description

StageOccupied
Start date
Occupation date
Location Highbury, North London London  England
Build typeNew build
Building sectorPrivate Residential
Property typeMid Terrace
Construction typeOther
Other construction typeDubel-Holz solid timber structural panels
Party wall construction
Floor area 291.9
Floor area calculation method Treated Floor Area (PHPP)
Building certification  Passivhaus certified building Passivhaus certified building

Project Team

Organisation4orm
Project lead person4orm
Landlord or ClientMatrix Bau
Architect4orm
Mechanical & electrical consultant
Energy consultant
Structural engineer
Quantity surveyor
Consultant
ContractorKauffman

Design strategies

Planned occupancy
Space heating strategy
Water heating strategy
Fuel strategy
Renewable energy strategy
Passive Solar strategy
Space cooling strategy
Daylighting strategy
Ventilation strategy
Airtightness strategy
Strategy for minimising thermal bridges
Modelling strategy
Insulation strategy
Other relevant retrofit strategies
Contextual information

Building services

Occupancy
Space heating
Hot water
Ventilation
Controls
Cooking
Lighting
Appliances
Renewable energy generation system
Strategy for minimising thermal bridges

Building construction

Storeys
Volume -
Thermal fabric area -
Roof description
Roof U-value -
Walls description
Walls U-value -
Party walls description
Party walls U-value -
Floor description
Floor U-value -
Glazed doors description
Glazed doors U-value - -
Opaque doors description
Opaque doors U-value - -
Windows description
Windows U-value - -
Windows energy transmittance (G-value) -
Windows light transmittance -
Rooflights description
Rooflights light transmittance -
Rooflights U-value -