Tackling low carbon retrofit of larger terraced housing in Conservation Areas

download as PDF
Download
as PDF
The proposed project addresses the need for carbon reduction in the environment of a Conservation Area within the context of a larger terraced victorian property. The proposal recognises the balance that needs to be maintained between traditional detail and aesthetics with carbon reduction by the introduction of the retrofit of insulation measures and new technologies.

Retrofit for the future ZA530K
Images Graphs Figures Description Strategies Building

Tackling low carbon retrofit of larger terraced housing in Conservation Areas : Project images

Click on image to preview full size

TSB_Houses_ZA530K_2.jpg
CO2 emissionsPrimary energy requirement
Energy target
Retrofit for the Future

Energy and fuel use

Fuel use by type
Primary energy requirement
CO2 emissions
Renewables

Measured data from renewable generation is not yet available.

Fuel use

 Pre-developmentForecastMeasured
Electricity use - - -
Natural gas use- - -
Oil use- - -
LPG use- - -
Wood use- - -
Other Fuel - - -
 Pre-developmentForecastMeasured
Primary energy requirement - - -
Annual CO₂ emissions - - -
Annual space heat demand - - -

Renewable energy

Electricity generationForecastMeasured
Renewables Technology--
Other Renewables Tech--
Electricity consumed by generation --
Primary energy requirement
offset by renewable generation
--
Annual CO₂ emissions
offset by renewable generation
--

Calculation and targets

Whole house energy calculation method SAP
Other whole house calculation method-
Energy target Retrofit for the Future
Other energy targets-
Forecast heating load -

Airtightness

 DateResult
Pre-development air permeability test--
Final air permeability test--

Project description

StageUnder construction
Start date15 March 2010
Occupation date25 June 2010
Location Liverpool Merseyside  England
Build typeRefurbishment
Building sectorPublic Residential
Property typeMid Terrace
Construction typeSolid Brick
Other construction type
Party wall construction
Floor area 160
Floor area calculation method Treated Floor Area (PHPP)
Building certification

Project Team

OrganisationConstructive Thinking Studio Limited
Project lead personJon Moorhouse Constructive Thinking Studio Limited
Landlord or ClientRiverside
ArchitectConstructive Thinking Studio Limited
Mechanical & electrical consultant
Energy consultant
Structural engineer
Quantity surveyor
Consultant
Contractor

Design strategies

Planned occupancyJul-12
Space heating strategySolar Thermal
Water heating strategySolar Thermal
Fuel strategy
Renewable energy strategyPV Slate
Passive Solar strategyThermal Mass
Space cooling strategyMVHR/ Opening Windows
Daylighting strategyExisting Window Openings
Ventilation strategyMVHR
Airtightness strategy Spray foam insulation and chimney closers
Strategy for minimising thermal bridges Spray foam insulation & careful window design & detailing
Modelling strategySAP 2005 + Extended worksheet EcoDesigner IES
Insulation strategyIcynene spray foam insulation
Other relevant retrofit strategies
Contextual information

Building services

OccupancyNULL
Space heatingNULL
Hot waterNULL
VentilationNULL
ControlsNULL
CookingNULL
LightingNULL
AppliancesNULL
Renewable energy generation systemNULL
Strategy for minimising thermal bridgesNULL

Building construction

Storeys 0
Volume -
Thermal fabric area -
Roof description NULL
Roof U-value 0.00 W/m² K
Walls description NULL
Walls U-value 0.00 W/m² K
Party walls description NULL
Party walls U-value 0.00 W/m² K
Floor description NULL
Floor U-value 0.00 W/m² K
Glazed doors description NULL
Glazed doors U-value 0.00 W/m² K -
Opaque doors description NULL
Opaque doors U-value 0.00 W/m² K -
Windows description NULL
Windows U-value 0.00 W/m² K -
Windows energy transmittance (G-value) -
Windows light transmittance -
Rooflights description NULL
Rooflights light transmittance -
Rooflights U-value 0.00 W/m² K